Class II Type A2, CE(06 series)

Airtech biological safety cabinet Class IIA2 airflow ratio is 70% recirculation and 30% exhaust, providing the protection to person, samples and environment from biological hazards and contamination. It equips with DC ECM motor for 60% energy saving, HEPA H14 filter efficiency 99.995%@0.3 micron which conforms EU standard EN1822.

The performance meets the standard YY0569, EN12469 and NSF/ANSI49.


ECM DC brushless motor 

CAV ( Constant air volume) technology

CPAS (Constant pressure apheresis system ) technology

The biological safety cabinet adopts  the ECM DC brushless motor working with the CPAS and CAV technology providing safe and reliable airflow volume and pressure during the operation in BSC.  Based on the ECM feature that can determine supply air volume and pressure by detecting changes in internal current and power, and realize automatic adjustment on the balance of air volume or pressure.The CPAS and CAV technologies are to precisely control airflow. When the cabinet is operated at set velocities and without read-justing the fan speed control, a 50% increase in pressure drop across the filter doesn't decrease total air delivery more than 10%.

The velocity meets USA NSF/ANSI49 standard  and EN12469 standard.

Integrated filtration system

USA HV brand HEPA Filter medium are applied in the supply H14 HEPA filter and exhaust HEPA filter guaranteeing the filtration efficiency ≥99.995% for 0.3micron particles ( Europe EN1822 standard ) providing strong filtration capability. The 2 HEPA filters are designed with the leakage resistance patent technology, ensuring the work area air cleanness at Class 5 (ISO14644.1 standard) . Therefore, it can provide the production in operated in clean environment. Optional U15 ULPA filter 99.9995% efficiency for partical size 0.12um.

Negative Pressure Protection

The work area is made of one piece of SUS304 plate without weld point, it supports the precisely controlled airflow forms to the biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. it reduce the contaminated air in work area to leakage to room and protects the operator in safety. Filtered air exhaust to room or outside. 

Approximately 30% of the air in the common plenum is exhausted through the HEPA filter to the room. The contaminated air filtrated by H14 HEPA filter and becomes clean air into the room. Advanced airflow sensors have a known standard of deviation exceeding safe airflow requirements by biological safety cabinets.

Humanized design

1. 6mm front sash window adopts hanging lifting system (Imported from Japan) ,using spring to limit the sash glass height level at arbitrary positioning, and avoid sash glass drop down suddenly. 

2. The interior work zone is made of one piece of SUS304 plate with round corner and no weld points, no leakage risk and easy for cleaning. The work zone is surrounded by negative pressure, ensuring the contaminated  air not leak outside.

3. Worktable is made of SUS304 plate and can be taken out.  It can be risen up by handle and support rode, convenient for cleaning.

4. The exterior is made of steel with sprayed powder, anti-bacteria and easy for cleaning. 

5. The base stand is equipped with mobile castors and leveling feet. 

Intelligent  smartflow control system

1. Angled color LCD display is easy to read the BSC working status.

2. Display blower, LED light, UV light and socket works condition.

3. Display downflow velocity  and inflow velocity, the velocity display accuracy is 0.001m/s, This is based on 2 independent sets of velocity sensors. 

4. Display filter life in percentage,  it reminds the user to  in safe condition to operate the BSC and change the filter in time.

5. Display time it is easy to know the operation time.   

6. Display UV timer. 

7. The controller is with password protection, the unauthorized person can not adjust the operating parameters. 





ModelBSC-1006IIA2BSC-1306IIA2BSC-1606IIA2BSC-1806IIA2
Nominal Size3 feet4 feet5 feet6 feet
Internal   Dimensions (W x D x H)1004*630*660 mm1304*630*660 mm1604*630*660 mm1804*630*660 mm
External   Dimensions (W x D x H)1200*785*2050 mm1500*785*2050 mm1800*785*2050 mm2000*785*2050 mm
TypeClass II, Type A2
Exhaust   DirectionTop Exhaust
Airflow   Pattern (downflow / exhaust)70% / 30%
Avarage   Inflow Velocity≥0.53m/s
Averrage   Downflow Velocity≥0.33m/s
BlowerDC ECM Blower
Work ZoneStainless Steel SUS304
Main BodyElectro-galvanized steel   with powder coated
Sash Glass   Thickness6mm
Sash Glass   TypeTempered Glass, UV-proof
Sash Working   Opening200mm
Sash Maximum   Opening500mm
Full Access   for Glass CleaningYes
Illumination   (Lx)≥1000
Noise (dB)≤65
CleanlinessHEPA: ISO Class 5 (Optional   U15 ULPA: ISO Class 4) 
Filtration   EfficiencyH14 HEPA:≥99.995%,@0.3 µm   (Optional U15 ULPA≥99.9995%,@0.12um)
Personnel   ProtectionTotal colony in impaction   sampler ≤10CFU./Time
Total   colony in slit type sampler ≤5CFU./Time
Product   ProtectionTotal colony in culture   dish  ≤5CFU./Time
Cross-contamination   ProtectionTotal colony in culture   dish ≤2CFU./Time
DisplayLCD Color Screen
Downflow   Velocity DisplayYes
Inflow   Velocity DisplayYes
Filter   Lifetime Display by %Yes
Blower SwitchYes
Brightness   Lamp SwitchYes
UV Lamp   SwitchYes
Socket Power   SwitchYes
UV TimerYes
Main Power   SwitchYes
Reated Power   (W)(without scoket)180220290330
AC220V,1Φ,50HZ/60HZYesYesYesYes
Net   Weight(kg)230260310350
Gross Weight262310358400
Alarm TypeSound+Flash
Sash Height   High/LowYes
Filter   BlockedYes
Filter   ShatturedYes
Filter   Lifetime RemindYes
Inflow   Velocity High/LowYes
Downflow   Velocity High/LowYes
DownflowHEPA Filter (Optional ULPA   filter)
ExhaustHEPA Filter (Optional ULPA   filter)
LED  Lamp1 pc
UV Lamp1 pc
Receptacle   (pieces)2 pcs
Water ValveOptional * 1 pc
Vacuum ValveOptional * 1 pc
StandYes
Adjustable   Feet4, as standard
Casters4, as standard